The FCC-300 Coriolis mass flowmeter is based on the principle of Coriolis force. When fluid flows in a vibrating measuring tube, a Coriolis force proportional to the mass flow rate is generated. By accurately detecting this mechanical signal, direct measurement of fluid mass flow rate can be achieved.
Characteristics:
MODBUS RTU Communication Protocol
Convenient Human-Machine Interface
Temperature and Pressure Compensation
Directly Measurable
Small Amplitude of the Measuring Tube
The FCC-300 Coriolis mass flowmeter has significant advantages in the field of fluid measurement due to its unique measurement principle. The specific advantages are as follows:
Accurate and reliable measurement:
Directly measuring fluid mass flow rate, unaffected by changes in fluid density, viscosity, temperature, pressure, etc., with high measurement accuracy and stable output of reliable data, providing accurate basis for production and measurement.
Wide range ratio is widely applicable:
With a wide range ratio, it can flexibly measure in a large flow range, whether it is small flow fine measurement or large flow industrial transportation monitoring, it can meet the needs of different working conditions.
Multi functional integration:
In addition to mass flow measurement, it can also simultaneously measure parameters such as fluid density and temperature, achieving integrated measurement of multiple parameters and reducing the number and cost of equipment installation.
Strong self diagnostic ability:
Equipped with comprehensive self diagnostic functions, it can monitor the operating status of sensors, circuits, and other components in real time, detect potential faults and alarms in a timely manner, and facilitate quick positioning and problem-solving.
Easy installation and maintenance:
Compact structure, low requirements for upstream and downstream straight pipe sections, flexible installation methods, can significantly reduce installation costs; The daily maintenance workload is small, reducing downtime and improving equipment operation efficiency.
Strong corrosion resistance:
Made of high-quality corrosion-resistant materials, suitable for measuring various corrosive media, it can also operate stably and have a long service life in highly corrosive industries such as chemical and pharmaceutical industries.








Diameter | U-type:DN20~DN150; Triangular:DN3~DN15; Straight Tube:DN8~DN80 |
Measurand | Mass flow,density,temperature |
Density accuracy | earth 0.002g/cm³ |
Accuracy | 0.1%,0.15%,0.2% |
Temperature | -40~+60℃ |
Power consumption | <15W |
Power supply | 220VAC ; 24VDC |
Signal output | 4~20mA, RS485, HART |
Ingress protection | IP67 |
Density range | (0.3~3.000)g/cm³ |
Repeatability | 1/2 of the measurement error |
Medium temperature | Standard type: (-50~200)℃, (-20~200)℃; High temperature type: (-50~350)°C; Low-temperature type: (-200~200)°C |
Process pressure | (0~4.0)MPa |
Humidity | 35%~95% |
Transmission output | (4~20) mA, output load (250~600) Ω |